The copper bonded rods are highly reliable and acknowledged globally due to its long run characteristics.

Copper Bonded Rods are low carbon high tensile steel rods with the minimum copper coating of 250 microns as per UL 467. The copper is molecularly bonded over the steel with the help of electroplating process which is making it a theft proof material. Thus, it offers remarkable electrical conductivity and high tensile strength.

Copper Bonded Rods are recommended by IS 3043: 2018, IEEE 80 and NBC 2016 for the earthing purpose. Based on solid rod technology, copper bonded rods are electrically and mechanically robust solution complying national and international standards. Each rod can be visually inspected to meet the requirements of IEC 62561-2. All the testing has been done as per UL 467 to ensure the best quality of the rods.

Also, Copper bonded steel rods shall be easily customized and are CPRI tested at different fault current carrying capacity as per various cross-sections of the rods.

 




Model

Model

•    UL listed rod of 12.8mm diameter with 10ft length.
•    UL listed rod of 14 mm diameter with 10ft length.
•    UL listed rod of 17.2 mm diameter with 10ft length.
•    UL listed rod of 19 mm diameter with 10ft length.
•    UL listed rod of 21 mm diameter with 10ft length.
•    UL listed rod of 23 mm diameter with 10ft length.
•    UL listed rod of 24 mm diameter with 10ft length.
•    UL listed rod of 25 mm diameter with 10ft length.
•    UL listed rod of 32 mm diameter with 10ft length.
•    UL listed rod of 38 mm diameter with 10ft length.
•    UL listed rod of 14 mm diameter with the length of 2meter.
•    UL listed rod of 17.2 mm diameter with the length of 2meter.

 

Feature

Feature

•    Certified product as per UL 467 and CPRI tested rod.
•    Fascinate 0% peeling on copper bonded rods.
•    Lifespan of more than 40 years with superlative performance.
•    Incorporation of less joints while implantation of rods
•    99.9% Copper coating over steel rod and theft-free solution.
•    Complying Standard  UL 467, IEEE 80, IEC 62561-2, NBC 2016 and IS 3043.
•    Magnificent flexibility uphold high strength due to low carbon steel.
•    Skillful capacity of handling fault current that other metals.

 

Research

Research

The complete real-time research conducted by National Electrical Grounding Research Project with collaboration of National Fire Protection Association. The purpose of research to check the tendency of copper bonded rods in comparison with galvanized rods. They placed both the rods in different types of soil in 1993 and taken away those rods in 2003. The outcome of rods is crystal clear, they found  galvanized rod fully languish along with heavy corrosion while copper bonded rods maintains its same glance. Thus, conclude the life of copper bonded rods are more than 40 years and the accountability  to examine the copper bonded rod construction is in hands of UL (Underwriters Laboratories).

Reference

reference

Complying Standards

•    IS 3043
•    NBC 2016
•    IEC 62561-2
•    IEEE 80
•    UL 467
•    BS 7430

 

 